Land
coverage area: 30% and F.A.R: 2.0 for commercial land.
Landcoverage area: 40% and F.A.R: 1.25 for Residential land.
Set
Back of houses of 10 mtr height, from front - 9 mtr, from back 3 mtr,
in both sides 3 mtr back.
Set Back
of houses of above 10 mtr height,
from front - 9 mtr, from back 5mtr, in both sides 5mtr set back.
Area
of Plot: Minimum 500 sq - mtr.
Land
coverage
area:
40% and F.A.R: 1.20 for commercial land.
Height:
Minimum
15 mtr.
Set Back
for house of 10 mtr height: upto 500 - 1000 sq mtr, front - 9 mtr,
back - 3 mtr and from both sides 3 mtr. more than 1000 sq mtr front -
9 mtr, back 4.5 mtr and from both sides 4.5 mtr.
Set
Back for houses of 10 - 15 mtr: more than 500 sq mtr, front - 9 mtr,
back - 5.0 mtr and from both sides 5 mtr.
Area of
Plot: Minimum 5000 sq mtr.
Land Coverage:
Maximum 5% mtr but minimum 500 sq mtr.
Height
Limit: 5 mtr maximum.
Specifications:
Shed should be constructed on pillars, whose wall's height should not be
more than 9.2 mtr.
Set
Back: Shed should be 15 mtr away from the border of the land. National
highway 75 mtr wide - distance should be 75 mtr from the centre of the
road, District highway/Urban Road, 45 mtr wide roads, - distance should
be 60 mtr from the centre of road. Main roads/30 mtr wide Rural / other
roads - - distance should be 30 mtr from the centre of road.
Roads:
Path leading to farm should be 9 mtr wide, there should be water bound
of minimum 3.5 mtr wide.
Afforestation/Plantation:
Minimum 40% of area should be covered, on which minimum 100 trees per
hectare should be planted.
Electricity
& Other Facilities: Landlord is self responsible for the amenities
in the farm house
Safety
Tank: should be 15 mtr away from the well
Scale &
Layout of Plot.
Filling
Station - (
77 mtr x 75 mtr):
land coverage (10%), F.A.R. (0.1), Front Set Back (3.0 mtr) and Height
(6.0 mtr)
Filling
Station - (
30 mtr x 79mtr):
land coverage (10%), F.A.R. (0.1), Front Set Back (3.0 mtr) and Height
(6.0 mtr)
Filling
Station cum Servicing Station- (
30 mtr x 36mtr):
land coverage (20%), F.A.R. (0.2), Front Set Back (6.0 mtr) and Height
(6.0 mtr)
Filling
Station cum Servicing Station- (
33 mtr x 45mtr):
land coverage (20%), F.A.R. (0.2), Front Set Back (6.0 mtr) and Height
(6.0 mtr)
Reachable
Path: 17
mtr wide
Area: minimum
1000 sq mtr.
Set Back:
around the land area 9.0 mtr
Shape of
Shed: minimum 1.2 mtr x 15 mtr
Height
of Building: minimum 6 mtr
Ventilation:
minimum 10% area reserved for windows and ventilator.
Reachable
Path: minimum 6 mtr wide
Area of
Land, Land coverage, F.A.R. & Set Back: minimum area 2000 sq mtr
Min
cattel 25: Area 2000, Land coverage 10%, F.A.R. 0.15 and Set Back
6 mtr
Min
cattel 50: Area 4000, Land coverage 10%, F.A.R. 0.15 and Set Back
9 mtr
Min
cattel 100: Area 7000, Land coverage 10%, F.A.R. 0.15 and Set Back
10mtr
Min
cattel 200: Area 7000, Land coverage 10%, F.A.R. 0.15 and Set Back
10mtr
Afforestation/Plantation:
minimum 50% part of the land reserved out of which 100 trees per hectare
should be implanted.
[
Best Viewed in Internet Explorer 5.0 & Later ] 800
px x 600 px